| Rating | 80 deg C, 600 Vac (jacket), Horizontal flame. |
|
| Conductor | 26 AWG - 20 AWG solid or stranded round, copper-clad steel, bare, tinned or silver- coated, having a minimum 40 per cent conductivity. |
|
| Insulation | PP, Over the conductor shall be applied a spiral wrap of PP thread nominally 35 mils in diameter, approximately 0.5 in. between turns. This assembly shall be enclosed with a PP tube having an approximately 25 mil wall. |
|
| Shield | A shield over the tube shall consist of a bare or tinned copper braid. A drain wire may be applied under the shield. |
|
| Jacket | PVC, 32 mils min average, 26 mils minimum at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | In electronic equipment where exposed to a temperature not exceeding 80 deg C and where the Jacket is exposed to a maximum operating potential of 600 Volts. |
|