APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1466 Issued:1969-04-17
Revised:2012-07-03
Style 1466 Single Conductor with Wxtruded Insulation and Extruded Jacket.

Rating60 deg C, 300V ac (jacket), Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round.
InsulationExtruded Foamed PE, 36 mils minimum average thickness, 32 mils minimum thickness at any point.
CoveringLacquered Rayon Braid.
ShieldOver Rayon Braid, consisting of 36-30 AWG copper applied as a wrap or braid; or Polyester-foil wrap with drain wire.
JacketExtruded PVC, 16 mils minimum average thickness, 13 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.