APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1471 Issued:1969-08-26
Revised:2012-11-30
Style 1471 Single conductor with extruded Insulation

Rating105 deg C, 125 Vac.
ConductorResistance Wire. Copper-Nickel, Chrome-Iron Alloy or Phosphor-Bronze Alloy conductor, 38 to 33 AWG, wound 20 to 45 turns per in on a core of Acrylic, Fiberglass, Rayon or Polyester.
InsulationExtruded PVC, 43 mils minimum average thickness, 39 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn electrically heated pads, and where the acceptability of the combination has been determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024