APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1475 Issued:1969-10-13
Revised:2012-03-09
Style 1475 Single-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, no voltage assigned, Horizontal flame.
Conductor28 AWG - 16 AWG solid or stranded round, tinned or bare.
InsulationExtruded PE, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
Shield38-30 AWG, tinned or untinned copper strands applied as a wrap or braid, a wrap of aluminum faced polyethylene terephthalate tape with a parallel uninsulated drain wire, or a wrap of copper foil.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of X-Ray equipment where not exposed to abuse.

UL and the UL Logo are trademarks of UL LLC © 2024