Rating | 60 deg C, 208 Vac, FT1 flame. |
|
Conductor | 14 or 12 AWG solid, Type TW wire. |
|
Insulation | Type TW insulated wire, the insulation shall be Blue in color to indicate 208 volt rating. |
|
Wrap | Paper wrap over insulation - Formed of four pieces of moisture resistant crepe type Kraft paper, 1 by 0.005 inch, or 1.5 by 0.003 inch, applied in a manner as to provide 5 thickness of paper over the labelled conductor with an approximate 0.1875 in. overlap between pieces. |
|
Covering | Glass or Combination Cotton-Glass braid saturated with a flame-ratardant and moisture-resistant impregnant. |
|
Covering | Optional. The over-all cable may be finished with an aluminum paint or white paint. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Only as factory assembled Non-Heating Leads on Radiant Heating Cable Units. |
|