Rating | 85 or 90 deg C, 600 Vac, Horizontal Flame. |
|
Conductor | 26 AWG -2 AWG. 26 AWG - 8 AWG, solid or stranded. 7 AWG -2 AWG, stranded only. |
|
Insulation | Extruded PVC. |
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 26-12 AWG | 12 mils | 9.5 mils |
| 11-8 AWG | 14 mils | 11.5 mils |
| 7-2 AWG | 20 mils | 17.5 mils |
|
Covering | Cotton or lacquered glass braid. |
|
Shield | Optional - Copper braid. |
|
Braid | Optional - Lacquered cotton braid. |
|
Covering | Optional - Extruded Nylon, 2 mil minimum thickness at any point. |
|
Covering | Optional - Extruded PVC. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| less than 0.375 inch | 15 mils | 8 mils |
| 0.375 inch or greater | 25 mils | 15 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. |
|