APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1507 Issued:1971-02-01
Revised:2012-05-02
Style 1507 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded.
InsulationExtruded PE or extruded FRPE, 31 mils min average, 28 mils minimum at any point.
ShieldShielding over conductor insulation shall consist of 36-30 AWG, tinned or untinned copper strands applied as a wrap or braid; or a wrap of aluminum faced Polyester tape with a parallel uninsulated drain wire.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-Up and Volume Control; or In the Internal Wiring of Appliances at temperatures not exceeding 80 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024