APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1519 Issued:1971-06-16
Revised:2012-02-02
Style 1519 Single Conductor with Extruded Insulation and Extruded Jacket

Rating80 deg C, 300 Vac, Horizontal Flame.
Conductor30 AWG - 16 AWG, Solid or Stranded Round.
InsulationExtruded PE, 26 mils minimum average, 23 mils minimum at any point.
ShieldAluminum faced mylar tape wrap with a bare drain wire; or 38-30 AWG, tinned or untinned copper strands applied as a wrap or a braid.
CoveringOptional - A textile braid or minimum 7 mils of Extruded PVC may be applied between the insulation and shield.
JacketExtruded PVC, 16 mils minimum average, 13 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024