APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1522 Issued:1971-06-25
Revised:2012-03-07
Style 1522 Single conductor wire using non-integral jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 22 AWG solid or stranded.
InsulationExtruded PE or extruded FRPE, 15 mils min average, 13 mils minimum at any point.
Shield38-30 AWG, tinned or untinned copper strands applied as braid or wrap; or wrap of aluminum faced Polyester tape with parallel, uninsulated drain wire applied over conductor assembly.
CoveringIndividual braids, cotton, rayon or fibered glass.
JacketExtruded PVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs phonograph pick-up cable and for electronic use in nonhazardous locations.