Rating | 60 deg C, 150 Vac, Horizontal flame. |
|
Conductor | 29 AWG - 20 AWG Stranded or Solid |
|
Insulation | FRPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point, approximately 0.5 inch between turns. This assembly shall be enclosed with a FRPE tube, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
Shield | A shield over the tube shall consist of a bare or tinned copper braid, or a wrap of aluminum faced Polyester tape. A drain wire may be applied under the shield. |
|
Jacket | PVC, 9 mils minimum average thickness, 8 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | In electronic equipment where the jacket is exposed to a maximum operating potential of 150 volts. |
|