APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1541 Issued:1972-01-24
Revised:2012-04-26
Style 1541 Single conductor cable using non-integral jacket

Rating80 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG. Solid or stranded copper wire with 30 AWG or smaller strandes, tinned or bare.
InsulationExtryded PE, 47 mils minimum average thickness, 43 mils minimum thickness at any point.
CoveringLacquered Rayon Braid.
ShieldOver Rayon Braid, consisting of 36-30 AWG copper applied as a wrap or braid.
JacketExtruded PVC, 20 mils minimum average thickness, 18 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.