APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1547 Issued:1972-04-24
Revised:2011-09-14
Style 1547 Single Conductor Cable with Extruded Non-Integral Jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 20 AWG, solid or stranded.
InsulationExtruded solid PE or extruded foamed PE, 22 mils minimum average thickness, 20 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded PVC, 22 mils minimum average thickness, 18 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024