APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1550 Issued:1972-05-25
Revised:2012-03-07
Style 1550 Single-conductor Cable using Non-Integral Jacket.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor36 AWG minimum.
InsulationExtruded PE, extruded foamed PE, extruded XLPE or extruded formed XLPE, 7 - 100 mils thickness.
CoveringOptional. Extruded PE, 2 - 10 mils thickness.
ShieldOptional.
CoveringOptional. Extruded PE, extruded foamed PE, extruded XLPE or extruded foamed XLPE, 7 - 100 mils thickness.
JacketExtruded PVC, 7 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.