Rating | 60 deg C, 300 Vac (Jacket), VW-1 flame. |
|
Conductor | 26 AWG - 20 AWG copper-clad steel, or copper alloy, bare tinned or silver coated. |
|
Insulation | PE, 25 mils min average, 22 mils minimum at any point. |
|
Assembly | Over the conductor shall be applied a spiral wrap of non-flame-retardant polyethylene thread, 25 mils min. avg. in diameter, approximately 0.375 in. between turns. This assembly shall be enclosed with a non-flame-retard- ant polyethylene tube having an approximately 25 mil min avg. wall. |
|
Shield | A shield over the nylon covered tube shall consist of a bare or tinned copper braid or a wrap of aluminum faced mylar tape with a parallel uninsulated drain wire. |
|
Covering | Optional. Extruded nylon covering, 3 mils min. avg., 2 mils minimum at any point may be applied over the tube. |
|
Jacket | PVC, 25 mils min average, 23 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of television sets, home entertainment and electronic equipment where the jacket is exposed to a maximum operating potential of 300 volts. |
|