Rating | 80, 90 or 105 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 2 AWG, solid or stranded. |
|
Insulation | Extruded PVC. |
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 30-10 AWG | 15 mils | 13 mils |
| 9-2 AWG | 30 mils | 27 mils |
|
Covering | Optional, Extruded PVC, 9 mils minimum average thickness, 8 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|