APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1571 Issued:1972-12-27
Revised:2015-02-14
Style 1571 Single conductor with extruded insulation

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG minimum. Solid or stranded.
InsulationExtruded PVC, SRPVC, foamed PVC, foamed SRPVC, XLPVC, XLSRPVC, foamed XLPVC or foamed XLSRPVC, 2 mils minimum thickness at any point, 100 mils maximum thickness.
CoveringOptional. Extruded PVC, Nylon, ETFE, Polyester, XLPVC, XL Nylon, XLETFE or XL Polyester, 2 mils minimum thickness at any point, or lacquered braid.
ShieldOptional.
JacketOptional. Same as covering.
ShieldOptional.
CoveringOptional. Same as covering.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024