APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1575 Issued:1972-12-19
Revised:2012-04-25
Style 1575 Single conductor with extruded insulation.

Rating60 deg C, 48 V, VW-1 flame.
Conductor18 AWG - 8 AWG, solid or stranded. Strands consisting of twisted or parallel lay.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal low voltage vehicle wire.