APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1590 Issued:1973-05-18
Revised:2012-07-16
Style 1590 Bonded or laminated flat ribbon cable.

Rating105 deg C, 90 Vac, Horizontal flame.
ConductorFlat, Bare copper. Width variable from 500-1500 mils. Thickness variable from 8-25 mils.
InsulationNon-extruded, PET, 4 mils min average.
AssemblyConsists of two layers of oriented polyethylene terephthalate tape; each layer backed with a 1 mil polyester adhesive. The first layer of tape, 1 mil thick, is longitudinally applied over the conductor, leaving an approximate 0.0625 inch spacing between the edges of the tape. The second layer of tape, 2 mils thick, is then longitudinally applied over the first layer, approximately centered over the spacing formed by the first tape and leaving an approximate 0.0625 inch spacing between the edges of the tape. Conductors shall be parallel.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.