Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 30 AWG minimum, solid or stranded. |
|
Insulation | Solid or foamed extruded PE, FRPE, XLPE or XLFRPE, 7 mils minimum thickness at any point, 100 mils maximum thickness. |
|
Covering | Optional. Extruded PVC, Nylon, or Polyester, 2 mils minimum thickness at any point, or lacquered braid. |
|
Shield | Non-ferous metallic braid or wrap; a wrap of aluminum- faced (one or both sides) PET tape with uninsulated drain wire or wires may be used. |
|
Jacket | Extruded PVC, 16 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
Shield | Nonferrous metallic braid or wrap; a wrap of aluminum faced (one or both sides) PET tape with uninsulated drain wire or wires may be used when the optional covering is employed. |
|
Jacket | Extruded PVC, 16 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment, Class 2 wiring systems. |
|