| Rating | 80 deg C, No Voltage Specified, Horizontal flame. |
|
| Conductor | 32 AWG minimum, solid or stranded. |
|
| Insulation | FRPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
| Shield | Optional. |
|
| Assembly | A spiral wrap of FRPE thread, 15 mils minimum diameter or heavier, applied over the conductor, approximately 1/2 inch between turns. This assembly shall be enclosed with a FRPE tube having 15 mils average thickness. |
|
| Covering | Inner covering - (Optional) - Extruded PVC, Nylon or polyester approximately 0.002 inch thick or lacquered braid. Non-Ferrous metallic braid or wrap. Outer covering - (Optional) - Extruded PVC, Nylon or polyester approximately 0.002 inch thick or lacquered braid. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring of electronic equipment. |
|