APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1606 Issued:1973-08-29
Revised:2012-03-09
Style 1606 Single Conductor Cable with Extruded Insulation

Rating105 deg C, 600 Vac, Horizontal flame, Moisture Resistant 75 deg C, Optional - Oil Resistant 60 or 80 deg C
Conductor8 AWG - 500 kcmil.
InsulationExtruded PVC.
Conductor sizeMinimum Average thicknessMinimum thickness at any point
8 AWG95 mils86 mils
6 AWG125 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerating Equipment orRoom Air Conditioners or Room Cooler Units or Internal Wiring of Remote Outdoor Condensing Units for Domestic Cooling Systems where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C), whichever is applicable. Moisture Resistant 75 deg C.