APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1611 Issued:1973-12-03
Revised:2011-08-26
Style 1611 Single conductor with extruded insulation.

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG min.
InsulationExtruded PVC, extruded foamed PVC, extruded XLPVC, or extruded foamed XLPVC. 7 mils minimum average.
ShieldOptional.
CoveringOptional. Over insulation or shield.
JacketExtruded PVC, 10 mils minimum average, 8 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Internal Wiring or External Patchcord in Class 2 Circuits of Electronic Components.

UL and the UL Logo are trademarks of UL LLC © 2024