Rating | 90 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 40 AWG - 18 AWG, solid or stranded. |
|
Insulation | (1). Tape wrap, solid PTFE, solid FEP, foamed PTFE, foamed FEP or solid PFA, 3 mils minimum, no specified maximum. Tape wrap may be one or more layers minimum 30 percent overlap of at least one layer; OR (2). Extruded PTFE, extruded FEP or extruded PFA, 3 mils min at any point; OR (3). May consist of one or two layers of above tape over above extruded insulation with minimum thickness of tape not specified. |
|
Shield | Optional. |
|
Covering | Optional. (1). Extruded PTFE, extruded PFA, extruded FEP, extruded ETFE, or tape wrap PTFE; OR (2). Spirally wrapped PETP tape using PVC or polyester adhesive. Lay not specified. |
|
Jacket | Extruded FEP, extruded PTFE, extruded PFA, extruded PVC or extruded ETFE, minimum 1.0 mils thick, or spirally wrapped with 1 mil thick PETP tape using PVC or Polyester adhesive. Lay not specified. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Class 2 circuits in equipment where not exposed to movement or mechanical abuse. |
|