APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1641 Issued:1974-11-13
Revised:2011-09-23
Style 1641 Triaxial Cable.

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor18 AWG - 12 AWG, solid or stranded.
InsulationExtruded foamed PE or extruded PE, 120 mils minimum average thickness, 100 mils minimum at any point.
AssemblyInsulated conductor with optional inner shield, inner jacket, optional outer shield, optional separator and outer jacket.
ShieldInner, optional.
JacketInner, extruded PE or extruded PVC, 23 mils minimum average thickness, 20 mils minimum at any point.
ShieldOuter, optional.
JacketOuter, extruded PVC or extruded CP or extruded Neoprene, 20 mils minimum average thickness, 16 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring of electronic equipment, Class 2 wiring systems.

UL and the UL Logo are trademarks of UL LLC © 2024