APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1661 Issued:1975-07-08
Revised:2012-04-27
Style 1661 Single Conductor with Extruded Insulation and Non-Integral Jacket.

Rating75 deg C, Voltage not specified, Horizontal flame.
Conductor(A) Solid, round or rectangular shaped copper conductor 26-19 AWG rectangular conductor. Maximum thickness of copper conductor is 13 mils, width of conductor variable. (B) Same as above; except 18-16 AWG rectangular conductor. Maximum thickness of copper conductor is 16 mils, width of conductor variable.
InsulationNylon, (A) 8.0 mils minimum avg., 6.0 mils minimum at any point wall of nylon. (B) 10.0 mils min avg., 8.0 mils min at any point wall of nylon. (See facing page for compounds designation).
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseVacuum cleaner power hose.

UL and the UL Logo are trademarks of UL LLC © 2024