APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1664 Issued:1975-08-14
Revised:2012-03-09
Style 1664 Single-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, No voltage assigned, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare.
InsulationExtruded PE or extruded FRPE, 20 mils minimum average thickness, 18 mils minimum thickness at any point.
ShieldMetal serve, braid, or equivalent, conductive thermoplastic with drain wire, or aluminum-faced Polyester with drain wire. Double shielding consisting of two or combination of two of the above may be employed.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of medical and dental electro- surgical hand instruments.