APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1675 Issued:1975-12-05
Revised:2011-11-09
Style 1675 Single-conductor cable with non-extruded jacket.

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, material not specified
InsulationExtruded ETFE, extruded FEP or extruded PTFE, 8 mils minimum average thickness, 6 mils minimum thickness at any point.
CoveringOptional, polyester in the form of a spiral wrap 1.0 mil minimum thickness.
ShieldOptional.
JacketPETP tape spiral wrapped with polyester or PVC adhesive, 3 mils minimum average thickness, 2 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024