APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1677 Issued:1976-01-07
Revised:2012-12-06
Style 1677 Single conductor with non-extruded insulation

Rating90 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, solid or stranded.
InsulationNon-extruded PETP tape and Polyester or PVC adhesive, 2 mils minimum average thickness 1.5 mils minimum thickness at any point.
AssemblyLaminated tape with oriented PETP and Polyester or PVC adhesive, spirally wrapped.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment in class 2 circuits only.