APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1691 Issued:1976-06-04
Revised:2014-06-25
Style 1691 Single conductor with extruded insulation

Rating80 deg C, 30 Vac, VW-1 flame.
Conductor40 AWG minimum, solid or stranded.
InsulationSolid or foamed, extruded PE or XLPE. 4 mils minimum thickness at any point, 100 mils maximum thickness.
CoveringOptional (required if outer covering is not employed) - 2 mils minimum thickness at any point, extruded PVC, Nylon, Polyester, PVDF, ETFE, XLPE or FRPE, or lacquered braids.
ShieldOptional.
CoveringOptional, 2 mils minimum thickness at any point, extruded PVC, polyester, Nylon, PVDF, ETFE or lacquered braid, or spiral wrap PETP tape with polyester adhesive, 0.5 mil minimum thickness at any point.
ShieldOptional.
CoveringOptional (required if inner covering is not employed), extruded PVC, 5 mils minimum thickness at any point, 40 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring of Low Energy Nonhazardous Circuits in Audio and Video Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024