Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 40 AWG min. Material not specified. |
|
Insulation | Extruded PE or extruded foamed PE or FRPE. May be irradiated. 7 mils min. at any point, 100 mils maximum (may be either tube and thread or pressure extruded). |
|
Shield | Optional. |
|
Covering | Extruded PVC: 7 mils minimum at any point, 100 mils maximum. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Class 2 Circuits in Electronic Equipment. |
|