Rating | 150 deg C, 150 Vac, Horizontal flame, Oil Res 60 deg C or 80 deg C (opt), Gasoline Resist (opt) |
|
Conductor | Solid or stranded or Litz cable magnet wire, R/C (OBMW2) magnet wire rated min 150 deg. C. AWG size to be determined by the Resistance Test per UL 1581. In addition, tinned copper may be employed when FEP insulation is used. |
|
Insulation | FEP or PFA or PTFE, TFE |
| 50-20 AWG | 5.5 mils min average | 5 mils min at any point |
| 19-15 AWG | 8 avg | 7 min |
| 14-10 AWG | 13 avg | 12 min |
| 9-6 AWG | 20 avg | 18 min |
| May extrude FEP in two or three layers. |
|
Assembly | Each single on magnet wire strand is cabled together other magnet wire strands to form a conductor. |
|
Shield | Optional. |
|
Covering | Optional, FEP, or PFA, 0.005 in or heavier or PTFE (extruded or tape wrapped) 0.005 in or heavier. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment, such as electronic computers and business machines, where not subjected to movement or mechanical damage. May also be used for further processing in cables and lead wire for UL 1950 applications. Tags may indicate the following:"300 peak Volts for Electronic Use Only"."Suitable for immersion in gasoline; gasoline vapor; and 60 deg. C or 80 deg. C in Oil". |
|