APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1719 Issued:1977-06-30
Revised:2012-04-27
Style 1719 Single Conductor with Extruded Insulation and Extruded Non-Integral Jacket.

Rating60 deg C, 30 Vac, VW-1 flame.
Conductor40 AWG minimum - material not specified.
Insulation7 mils minimum at any point, 100 mils maximum. Solid or Cellular PE, FRPE, or PVC. May be Irradiated.
ShieldOptional.
JacketExtruded PVC, 8 mils minimum average thickness at any point, 100 mils maximum.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring of Low Energy Non-Hazardous Circuits in Audio and Video Equipment.