Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 40 AWG minimum |
|
Insulation | Extruded PE or extruded cellular PE or extruded FRPE or extruded cellular FRPE or extruded XLPE or extruded cellular XLPE, 15 mils minimum thickness at any point, 125 mils maximum thickness at any point. The insulation may be applied directly over the conductor or applied as a spiral wrapped PE thread (5 mils minimum thickness at any point, 40 mils maximum thickness at any point) and enclosed with "tubed on" insulation. |
|
Assembly | Insulated conductor with optional covering, inner shield, inner jacket, outer shield, optional separator and outer jacket. |
|
Covering | Optional - Extruded PVC, Polyamide, Polyester, PVDF, ETFE or lacquered braids, 2 mils min. at any point. |
|
Inner Shield | In accordance with the Standard |
|
Inner Jacket | Extruded PVC or extruded Nylon or extruded Polyester or extruded PVDF or extruded ETFE, 15 mils minimum thickness at any point; or lacquered braid. |
|
Outer Shield | In accordance with the Standard |
|
Separator | Optional - Paper |
|
Outer Jacket | Extruded PVC, 15 mils minimum thickness at any point |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electronic Equipment. |
|