APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1722 Issued:1977-07-19
Revised:2012-04-02
Style 1722 Single Conductor with Extruded Insulation

Rating125 deg C, 600 Vac, Horizontal flame.
Conductor30 AWG - 4/0 AWG solid or stranded round, tinned or bare - min 90% conductivity.
InsulationExtruded TPE
AWG Conductor SizeMinimum average thickness (mils)Minimum thickness at any point (mils)
30-93027
84540
7-26054
1-4/08064
Covering(Optional) Braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as Motor Leads or Internal Wiring of Appliances. Tags may indicate the following: 2500 V Peak - For Electronic Use Only.

UL and the UL Logo are trademarks of UL LLC © 2024