Rating | 250 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 32 AWG - 4/0 AWG, solid or stranded. |
|
Insulation | Extruded MFA or PFA. |
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 32-10 AWG | 13 mils | 12 mils |
| 8-6 AWG | 20 mils | 18 mils |
| 4-2 AWG | 30 mils | 27 mils |
| 1-4/0 AWG | 45 mils | 40 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances or electronic equipment. |
|