| Rating | 60, 80, 90, 105 deg C, 30 Vac, Horizontal flame. |
|
| Conductor | 40 AWG min., solid or stranded. |
|
| Insulation | Extruded PVC, extruded foamed PVC, extruded XLPVC or extruded foamed XLPVC, 2 mils min at any point - 100 mils thickness. |
|
| Covering | Optional. Extruded PVC, extruded Nylon (Polyamide), extruded Polyester or lacquered braid. |
|
| Shield | Optional. |
|
| Jacket | Optional. Extruded PVC, extruded Nylon (Polyamide) or extruded Polyester, 2 mils min average. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal Wiring of Class 2 Circuits in Electronic Equipment. |
|