APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1742 Issued:1978-02-22
Revised:2011-09-14
Style 1742 Single conductor with extruded insulation.

Rating60, 80, 90, 105 deg C, 600 Vac, (2500 Volts peak). VW-1 flame.
Conductor22 AWG - 14 AWG solid or stranded round, tinned or bare copper.
InsulationPVC, Inner Layer - 30 mils minimum average thickness, 27 mils minimum thickness at any point. Outer Layer - 28 mils minimum thickness at any point; average thickness not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseDoubly protected internal wiring for use in television receivers and video products.