|
Rating | 60, 80 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 40 AWG - 18 AWG solid or stranded round. |
|
Insulation | Extruded PVC, 10 mils minimum thickness average, 9 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electronic Equipment and Business Machines when used within a chassis or protected from mechanical injury. |
|