APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1770 Issued:1978-12-22
Revised:2012-04-25
Style 1770 Single-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare, copper, copper clad steel, or copper alloy.
InsulationSolid or cellular PP, 25 mils min average, 22 mils minimum at any point.
ShieldMetal serve, braid, or equivalent, conductive thermoplastic with drain wire, or aluminum-faced Polyester with drain wire. Double shielding consisting of two or combination of two of the above may be employed.
CoveringOptional. A textile braid, nylon jacket (2 mil min thickness) or min 8 mils of semirigid or regular PVC may be applied between the insulation and shield.
JacketOver the shielding a PVC, 16 mils min average, 13 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.