Rating | 90 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 40 AWG minimum, material not specified. |
|
Insulation | Extruded FEP or PFA, 8 mils min average. |
|
Assembly | Consists of inner layer of FEP or PFA braid covered by spirally wrapped oriented polyethylene terephthalate tape with polyester adhesive. |
|
Shield | Optional. |
|
Jacket | Oriented polyethylene Terephthalate tape spirally wrapped with polyester adhesive 0.6 mil at any point, or extruded PVDF or ETFE, 2 mil minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Classifications of Class 2 Circuits in Electronic Equipment. |
|