APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1774 Issued:1979-02-28
Revised:2012-07-12
Style 1774 Single Conductor Cable with Extruded Insulation with an Extruded Non-integral Jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationExtruded PVC, 15 mils min average, 13 mils minimum at any point.
ShieldOptional.
JacketExtruded PVC, 30 mils min average, 27 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024