APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1792 Issued:1979-05-30
Revised:2017-09-07
Style 1792 Single conductor with extruded insulation

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum.
InsulationExtruded solid FRPE, extruded solid PE, extruded solid PVC, extruded foamed FRPE, extruded foamed PE, extruded foamed PVC, extruded solid XLPE, extruded solid XLPVC, extruded foamed XLPE, or extruded foamed XLPVC, 2 mils minimum thickness at any point, 100 mils maximum.
ShieldOptional.
CoveringInner Covering - (Optional) 2 mils minimum thickness at any point of - Extruded PVC, extruded Nylon (Polyamide), extruded PVDF or extruded ETFE or lacquered braid. ;Outer Covering - (Optional) - Extruded PVC, 7 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024