APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1796 Issued:1979-07-20
Revised:2012-07-06
Style 1796 Single Conductor with Extruded Insulation - Heating Wire.

Rating105 deg C, 125 Vac.
Conductor36 AWG - 34 AWG Resistance Wire. Construction A- Copper-nickel alloy conductor, 34 AWG, wound 20 to 40 turns per inch on a core of Polyester, Acrylic, Fiberglass, Rayon or Polyester. Construction B- Chrome-iron alloy conductor, 36 AWG wound 25 to 45 turns per inch on a core of Polyester, Acrylic, Fiberglass, Rayon or Polyester.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024