Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 16 AWG solid or stranded round. |
|
Insulation | Extruded XLPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
Shield | Optional. |
|
Covering | Optional. A Fibrous braid, nylon (2 mil min. thickness), or min 8 mils of semi-rigid or regular PVC may be applied between the insulation and shield. |
|
Jacket | Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Electronic Equipment. |
|