Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 4/0 AWG solid or stranded. |
|
Insulation | Exturded PVC |
| 30-16 AWG conductor size | 15 mils min average | 13 mils minimum at any point |
| 15-10 AWG | 30 avg | 27 min |
| 9-8 AWG | 45 avg | 40 min |
| 7-2 AWG | 60 avg | 54 min |
| 1-4/0 AWG | 80 avg | 72 min |
|
Shield | Braid or spiral wrap construction using steel, nickel-tin, or copper-plated steel, or copper-plated iron alloy, or copper-plated nickel wires. |
|
Jacket | Extruded PVC |
| Conductor Size (AWG) | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 30-16 | 15 | 12 |
| 15-2 | 30 | 27 |
| 1 - 4/0 | 45 | 40 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Electronic equipment where not subjected to repeated flexing in end application. |
|