APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1819 Issued:1980-02-15
Revised:2011-08-26
Style 1819 Single conductor with extruded insulation.

Rating80 deg C, 30 Vac, VW-1 flame.
Conductor40 AWG minimum.
InsulationExtruded PE, extruded foamed PE, extruded XLPE, or extruded foamed XLPE. 4 - 100 mils.
ShieldOptional.
CoveringInner covering - (Optional) 2 mils minimum at any point extruded PVC, Polyamide, Polyester, PVDF, ETFE or Lacquered Braid. Outer covering - same as inner covering.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring of Low Energy Non-Hazardous Circuits in Audio and Video Equipment where not subjected to repeated flexing in end application.

UL and the UL Logo are trademarks of UL LLC © 2024