| Rating | 80 deg C, 10000 Vac, Horizontal Flame. |
|
| Conductor | Carbon impregnated glass fiber thread may be covered with carbon impregnated glass fiber braid. Approximately 63 mils diameter, 5-30 Kohms per meter D. C. resistance. |
|
| Insulation | Extruded FRPE, 50 mils minimum average, 45 mils minimum at any point. See Facing Page for Compound Identification. |
|
| Covering | Extruded PE, 7 mils minimum average, 5 mils minimum at any point. |
|
| Misc. | Separator - Extruded conductive thermoplastic PE over the conductor assembly. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring where not subjected to repeated flexing. |
|