Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 40 AWG minimum, material not specified. |
|
Insulation | FRPE or PE or XLPE, solid or Cellular, 5 mils minimum at any point, 125 mils maximum. |
|
Assembly | The insulation is applied directly over the conductor or applied as a spiral wrapped Polyethylene thread (5 mils minimum, 40 mils maximum) and enclosed with "tubed on" insulation. |
|
Shield | Optional. |
|
Covering | Inner covering - (Optional) Extruded PVC or heat sealed PVC tape, Polyamide, Polyester, PVDF, ETFE or lacquered braids, 2 mils minimum at any point or 0.5 mil or heavier Polyester film. Outer covering - (1) Not required over aluminum-faced Polyester tape. (2) Optional over shield. Extruded PVC or heat sealed PVC tape, Polyamide, Polyester, PVDF, ETFE, Irradiated PE, Irradiated PVC or lacquered braid, 2 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | As insulated singles in external interconnection cable for electronic equipment, Class 2 wiring systems. |
|