APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1830 Issued:1980-09-25
Revised:2011-09-14
Style 1830 Single conductor with extruded insulation.

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, material not specified.
InsulationFRPE or PE or XLPE, solid or Cellular, 5 mils minimum at any point, 125 mils maximum.
AssemblyThe insulation is applied directly over the conductor or applied as a spiral wrapped Polyethylene thread (5 mils minimum, 40 mils maximum) and enclosed with "tubed on" insulation.
ShieldOptional.
CoveringInner covering - (Optional) Extruded PVC or heat sealed PVC tape, Polyamide, Polyester, PVDF, ETFE or lacquered braids, 2 mils minimum at any point or 0.5 mil or heavier Polyester film. Outer covering - (1) Not required over aluminum-faced Polyester tape. (2) Optional over shield. Extruded PVC or heat sealed PVC tape, Polyamide, Polyester, PVDF, ETFE, Irradiated PE, Irradiated PVC or lacquered braid, 2 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs insulated singles in external interconnection cable for electronic equipment, Class 2 wiring systems.

UL and the UL Logo are trademarks of UL LLC © 2024