Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Conductor | No. 35 AWG minimum, solid or stranded. |
|
Insulation | Solid or cellular XLFRPE or FRPE or XLPE or PE or XLPP or PP, 7 mils min at any point. |
|
Assembly | Insulated conductor with optional inner covering, outer conductor, optional outer covering. When an aluminum/polyester tape is employed, the outer covering may be omitted. |
|
Shield | Optional. |
|
Covering | Inner covering - Optional, Extruded PVC, PE, Polyamide or Polyester approximately 0.002 in. thick or lacquered braid, or spiral wrap of minimum 0.0005 in. thick polyester tape applied with approx. 50 percent overlap.
Outer covering - Required when an aluminum/polyester tape shield is not employed, Optional when an aluminum/polyester tape shield is employed, Extruded PVC, PE, Polyamide or Polyester approximately 0.002 in. thick or spiral wrap of minimum 0.0006 in. thick polyester tape applied with approx. 50 percent overlap, or lacquered braid. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For Further Processing into Cables. |
|