APPLIANCE WIRING MATERIAL
Subj.758
Section
1
Page
1845
Issued:
1981-05-14
Revised:
2008-05-27
Style
1845
Insulated Wire.
Rating
105 deg C, 300 Vac, Horizontal flame.
Conductor
Resistance Wire, solid or stranded, 24 AWG min.
Insulation
TPE, 30 mils min average, 27 mils minimum at any point.
Covering
Optional. Braid and/or shield.
Jacket
TPE, 30 mils min average, 24 mils minimum at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Heating Cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.
UL and the UL Logo are trademarks of UL LLC © 2024